INTRODUCTION
The Vertical Foam Bladder Tank is the main unit of the foam extinguishing system. The foam tank and the low/medium expansion foam generator construct the low/medium foam spraying system. It can also construct the high expansion total flooding extinguishing system with high expansion foam generator.
PRINCIPLE
The device consists of pressure tank, bladder, proportioner, pressure gauge, valves and pipeline. A pump is needed to supply pressurized water. When pressurized water flow though proportioner, a small part of water (3%-6%) flow into tank from branch pipe to press the bladder to swap out equal foam concentrate and then mix with another part of water (97%-93%) to form foam solution in proportioner and provide to foam generator.
PARAMETERS
Proportioner Model No. | PHY4 | PHY8 | PHY16 | PHY24 | PHY32 | PHY40 | PHY64 | PHY72 |
Diameter (DN) | 50 | 65 | 80 | 100 | 100 | 150 | 150 | 150 |
Mixing Ratio | 3% or 6% | |||||||
Rated Working Pressure (MPa) | 1.2 | |||||||
Working Pressure Range (MPa) | 0.3~1.2 | |||||||
Rated Flow (L/S) | 4 | 8 | 16 | 24 | 32 | 40 | 64 | 72 |
Flow Rang (L/S) | 1~4 | 2~8 | 3~16 | 4~24 | 8~32 | 12~40 | 15~64 | 17~72 |
Pressure Drop (MPa) | ≤0.2 |
INSTALLATION
Device should be installed at places with shelter to avoid sun and rain. Ambient temperature should be within 40°C and leave enough space for operation. Device should be installed at concrete floor and fastened with anchor nuts.
Do the hydraulic test after installing. Open the tank vent valve first then fill water into bladder from concentrate draining pipe. Then close tank vent valve when bladder is full of water. Pressurize the system and keeping for 10 minutes when pressure gets test pressure, tank should have no leakage. Close water inlet valve and open water drainage valve and concentrate drainage valve to drain water away in tank and bladder. (We will do this test when products leave the factory)
CAPACITY LITERS | D mm | L mm | L1 mm | B mm | B1 mm | H mm | H1 mm | WEIGHT (KG) |
500 | 800 | 810 | 600 | 1000 | 1150 | 1700 | 1200 | 280 |
1000 | 1000 | 1010 | 800 | 1200 | 1350 | 2100 | 1200 | 350 |
1500 | 1200 | 1210 | 1000 | 1400 | 1550 | 2100 | 1200 | 450 |
2000 | 1400 | 1410 | 1200 | 1600 | 1750 | 2050 | 1200 | 550 |
3000 | 1400 | 1410 | 1200 | 1600 | 1750 | 2450 | 1200 | 800 |
4000 | 1600 | 1600 | 1400 | 1800 | 1950 | 2800 | 1200 | 1050 |
5000 | 1700 | 1680 | 1500 | 1900 | 2050 | 3000 | 1200 | 1200 |
6000 | 1800 | 1760 | 1600 | 2000 | 2150 | 3300 | 1200 | 1400 |
8000 | 1900 | 1820 | 1700 | 2100 | 2250 | 3800 | 1200 | 1600 |
9000 | 2000 | 1920 | 1800 | 2200 | 2350 | 3900 | 1200 | 1900 |
10000 | 2200 | 2120 | 2000 | 2400 | 2550 | 4300 | 1200 | 2200 |
Characteristics of foam tank
1. The foam tank has stable mixing ratio and high reliability, and can provide high-quality foam mixed liquid.
2. The foam tank has the smallest pressure drop, the sprayed foam extinguishing agent has large energy and strong penetrating ability. Can quickly put out the fire.
3. Save foam liquid and reduce fire extinguishing costs. Because the capsule of the foam tank separates the foam liquid from the water, the foam liquid is not used up at one time and can be used next time, and the mixing accuracy is stable and reliable.
4. It has a wide range of applications, no matter high, medium or low expansion foam fire extinguishing agent can be used. The foam ratio mixing device of the automatic foam fire extinguishing system can be used with foam nozzles or sprinklers.
Size and weight are just for reference, real products can be different.
FAQ
1. What is the minimum order quantity for your product?
The minimum order quantity is one set/set.Foam liquid is generally 1000 liters
2. Do you have your own factory manufacturer?
Yes, we have been a manufacturer for more than 20 years. Our main products are foam fire extinguishing equipment, bladder storage tank foam system, balanced pressure distribution system, etc. We can provide a one-stop service including fire protection products.
3. What are your payment terms?
We accept wire transfer, letter of credit, Western Union, Paypal, etc.
4. How long is the delivery time?
Usually about 15 days after payment, if you have custom or other requirements for delivery time, you need to communicate again.
5. Can OEM be accepted?
Yes, we provide customized designs for customers.
Feel free to contact us!